VD Bio Medisystems (VD-9000T) Cardiac Patient Monitor With Touch Screen

VD Bio Medisystems (VD-9000T) Cardiac Patient Monitor With Touch Screen

VD Bio Medisystems (VD-9000T) Cardiac Patient Monitor With Touch Screen

VD Bio Medisystems (VD-9000T) Cardiac Patient Monitor With Touch Screen

Manufacturer/Marketer :
VD Bio Medisystems

In stock

Features
  • 12.1" TFT color LCD With Touch Screen Display multi-language interface.
  • Fanless design, quiet, energy-saving, and clean, which reduces the possibility of cross-infection.
  • All-round monitor for adult, pediatric, and neonate.
  • With the standard interface, oxygen graph, trend graph, big character interface, and view bed, convenient to observe.
  • Finish all operations with keys and knobs.
  • Maximum 8-channel waveform synchronous display.
  • Display 7-lead ECG waveform on one screen, cascade ECG waveform display.
  • Adopt digital SpO2 technology, anti-motion, and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling.
  • Heart rate variability (HRV) analysis function
  • NIBP measurement mode: Manual/AUTO/STAT, storage for 4800-group NIBP data.
  • Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.
  • Drug concentration calculation and titration table functions.
  • One-touch printing of trend graph
  • Connect to Central Monitoring System by 3G, Wi-Fi, or wired mode.
  • AC/DC, built-in rechargeable lithium battery achieves uninterrupted monitoring.
  • Anti-high frequency surgical unit, defibrillation-proof (special leads are necessary).

Specifications:

  • Standard parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP
  • ECG Heart rate (HR)
  • ECG waveform
  • Arrhythmia and ST-segment analysis
  • RESP Respiration rate(RR)
  • Respiration waveform
  • SpO2 Oxygen saturation(SpO2)
  • Plethysmogram(PLETH) waveform
  • Pulse rate(PR)
  • Bar graph
  • NIBP Systolic pressure (SYS), Diastolic pressure(DIA), Mean pressure (MEAN)
  • TEMP T1, T2, TD
  • IBP(optional) CH1: SYS, DIA, MAP
  • CH2: SYS, DIA, MAP
  • IBP waveform
  • CO2 EtCO2 Optional
  • InsCO2:Inspired Minimum CO2
  • AwRR: Air Way Respiration
  • It has abundant functions, such as audible and visual alarms, trend data storage and output, NIBP measurement, alarm event marking, and drug concentration calculation etc.

ECG

  • Lead mode: 3-lead or 5-lead
  • Lead selection: I, II, III, aVR, aVL, aVF, V
  • Waveform: 5-lead, dual-channel
  • 3-lead, single-channel
  • Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV

HR:

  • Scan speed: 12.5mm/s, 25 mm/s, 50 mm/s
  • Measurement and alarm range: 15~350 bpm
  • Accuracy: ±1% or ±1 bpm, whichever is greater
  • Alarm accuracy: ± 2 bpm
  • Resolution: 1 bpm
  • ST-segment monitoring:
  • Measurement and alarm range: -2.0 mV ~ +2.0 mV
  • Accuracy: -0.8 mV~+0.8 mV ±0.04 mV or ±10%, whichever is greater
  • Other range: unspecified
  • Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2,
  • PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
  • Pacemaker: yes

RESP

  • Method: R-F(RA-LL) Impedance
  • Respiration rate:
  • Measurement and alarm range: 0~150 rpm
  • Resolution: 1 rpm
  • Measurement accuracy: ±2 rpm
  • Alarm accuracy: ±3 rpm
  • Apnea alarm: 10~40s
  • Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s

NIBP

  • Method: Oscillometry
  • Mode: Manual/AUTO/STAT
  • Measurement interval inAUTO  mode :    1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutes
  • Measurement period in STAT mode: 5 minutes
  • Measurement and alarm range: 10 ~ 270 mmHg Resolution: 1 mmHg
  • Cuff pressure accuracy: ±3 mmHg
  • Measurement accuracy:
  • Maximal mean deviation: +5 mmHg
  • Maximal standard deviation: 8 mmHg
  • Over-pressure protection
  • Adult mode: 297+3 mmHg
  • Pediatric mode: 240+3 mmHg
  • Neonatal mode: 147+3 mmHg

SpO2

  • Measurement and alarm range: 0
  • Resolution: 1>%
  • Measurement accuracy: 70%-100%: +2%;
  • 0%-69%: unspecified

PR

  • Measurement and alarm range: 30~250 bpm
  • Measurement accuracy: ±2 bpm or ±2%, whichever is greater

TEMP

  • Channel: dual-channel
  • Measurement and alarm range: 0 ~ 50°C
  • Resolution: 0.1 °C
  • Accuracy: ±0.1 °C

EtCO2

  • Method: Sidestream or Mainstream
  • Measuring Range: 0~150mmHg

Resolution

  • 0-69 mmHg, 0.1 mmHg
  • 70-150 mmHg, 0.25 mmHg

Accuracy

  • 0-40 mm Hg ±2 mm Hg
  • 41-70 mm Hg +5>%
  • 71~100 mm Hg ±8>%
  • 101-150 mm Hg ±10>%
  • AwRR Range: 2~150 rpm
  • AWRR Accuracy: ±1BPM Apnea Alarm: Yes

Accessories

  • Adult fingertip SpO2 probe (5-pin)
  • Adult NIBP cuff
  • NIBP extension tube
  • ECG lead cable
  • ECG electrode
  • Temperature probe
  • Power cord
  • User Manual

 

Do you want to purchase in bulk ?

Please fill out the form below, We'll get back to you.

flag

+91

BULK PURCHASE

Related Products

Share Your Requirements With Us

Please fill out the form below. We'll get back to you. Thank you for your patience.

Save to Quick Order List

New Quick Order List

icon
Do you want to purchase in bulk ?

Please fill out the form below, We'll get back to you.

flag

+91