Features
  • 12.1" TFT color LCD with a multi-language interface.
  • Fanless design for quiet operation, energy savings, and cleanliness, reducing the risk of cross-infection.
  • Comprehensive monitoring for adults, pediatrics, and neonates.
  • Features a standard interface, oxygen graph, trend graph, large character interface, and bed view for convenient observation.
  • All operations can be completed using keys and knobs.
  • Supports maximum 8-channel synchronous waveform display.
  • Displays 7-lead ECG waveforms on one screen with cascade ECG waveform display.
  • Utilizes digital SpO2 technology that is resistant to motion and ambient light interference, allowing measurements even under conditions of weak perfusion.
  • Includes heart rate variability (HRV) analysis function.
  • NIBP measurement modes: Manual, AUTO, and STAT, with storage for 4,800 NIBP data points.
  • Allows review of 71 alarm events across all parameters and 60 arrhythmia alarm events.
  • Features drug concentration calculation and titration table functions.
  • One-touch printing of trend graphs.
  • Connects to Central Monitoring System via 3G, Wi-Fi, or wired mode.
  • AC/DC operation with a built-in rechargeable lithium battery for uninterrupted monitoring.
  • Designed to be resistant to high-frequency surgical units and defibrillation-proof (special leads are necessary).

Specifications:

  • Standard parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP
  • ECG Heart rate (HR)
  • ECG waveform
  • Arrhythmia and ST-segment analysis
  • RESP Respiration rate(RR)
  • Respiration waveform
  • SpO2 Oxygen saturation(SpO2)
  • Plethysmogram(PLETH) waveform
  • Pulse rate(PR)
  • Bar graph
  • NIBP Systolic pressure (SYS), Diastolic pressure (DIA), Mean pressure(MEAN)
  • TEMP T1, T2, TD
  • IBP(optional) CH1: SYS, DIA, MAP
  • CH2: SYS, DIA, MAP
  • IBP waveform
  • CO2 EtCO2 Optional
  • InsCO2:Inspired Minimum CO2
  • AwRR: Air Way Respiration
  • It has abundant functions, such as audible and visual alarms, trend data storage and output.

ECG:

  • Lead mode: 3-lead or 5-lead
  • Lead selection: I, II, III, aVR, aVL, aVF, V
  • Waveform: 5-lead, dual-channel
  • 3-lead, single-channel
  • Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV
  • Scan speed: 12.5mm/s, 25 mm/s, 50 mm/s

HR:

  • Measurement and alarm range: 15~350 bpm
  • Accuracy: ±1% or ±1 bpm, whichever is greater
  • Alarm accuracy: ± 2 bpm
  • Resolution: 1 bpm
  • ST-segment monitoring:
  • Measurement and alarm range: -2.0 mV ~ +2.0 mV
  • Accuracy: -0.8 mV~+0.8 mV ±0.04 mV or ±10%, whichever is greater
  • Other range: unspecified
  • Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2,
  • PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
  • Pacemaker: yes

RESP:

  • Method: R-F(RA-LL) Impedance
  • Respiration rate:
  • Measurement and alarm range: 0~150 rpm
  • Resolution: 1 rpm
  • Measurement accuracy: ±2 rpm
  • Alarm accuracy: ±3 rpm
  • Apnea alarm: 10~40s
  • Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s

NIBP

  • Method: Oscillometry
  • Mode: Manual/AUTO/STAT
  • Measurement interval in AUTO mode:
  • Measurement period in STAT mode: 5 minutes
  • Measurement and alarm range: 10 ~ 270 mmHg . Resolution: 1 mmHg
  • Cuff pressure accuracy: ±3 mmHg
  • Measurement accuracy:
  • Maximal mean deviation: +5 mmHg
  • Maximal standard deviation: 8 mmHg
  • Over-pressure protection:
  • Adult mode: 297+3 mmHg
  • Pediatric mode: 240±3 mmHg
  • Neonatal mode: 147+3 mmHg

SpO2

  • Measurement and alarm range: 0 100>%
  • Resolution: 1>%
  • Measurement accuracy: 70% ~100%: +2%;
  • 0%-69% unspecified 

PR

  • Measurement and alarm range: 30 ~ 250 bpm
  • Measurement accuracy: ±2 bpm or ±2%, whichever is greater

TEMP

  • Channel: dual-channel
  • Measurement and alarm range: 0 50°C
  • Resolution: 0.1 °C
  • Accuracy: ±0.1 °C

EtCO2

  • Method: Sidestream or Mainstream
  • Measuring Range: 0~150mmHg

Resolution:

  • 0-69 mmHg, 0.1 mmHg
  • 70-150 mmHg, 0.25 mmHg

Accuracy:

  • 0-40 mm Hg ±2 mm Hg
  • 41-70 mm Hg +5>%
  • 71~100 mm Hg ±8>%
  • 101-150 mm Hg ±10>%
  • AwRR Range: 2~ 150 rpm AWRR Accuracy: ±1BPM
  • Apnea Alarm: Yes

Accessories

  • Adult fingertip SpO2 probe (5-pin)
  • Adult NIBP cuff
  • NIBP extension tube
  • ECG lead cable
  • ECG electrode
  • Temperature probe
  • Power cord
  • User Manual
Do you want to purchase in bulk ?

Please fill out the form below, We'll get back to you.

flag

+91

BULK PURCHASE

Related Products

Share Your Requirements With Us

Please fill out the form below. We'll get back to you. Thank you for your patience.

Save to Quick Order List

New Quick Order List

icon
Do you want to purchase in bulk ?

Please fill out the form below, We'll get back to you.

flag

+91