Create your quick order from the list of frequently ordered and recently purchased products and free yourself from the hassle of searching for , adding products to cart and checking out
Click the bookmark icon in product listing to effortlessly add products to your quick order and conveniently organise them into different categories tailored to your needs
All available standard brands of syringes. Custom Programmable to any brand Syringe.
FLOW RATE RANGE
0.1-999.9m/Hr (Depending on syringe size)
INFUSED VOLUME RANGE
0.1-999.9ml
BOLUS RATE & VOLUME
300-999.9ml/hr (Depending on syringe size), Volume is Programmable by user
BOLUS INTERVAL
A minimum interval of time can be preset between two Bolus dose to avoid accidental over infusion, 1 min to 24 Hrs.
PURGE FACILITY
KVO
To Prevent Needle Clogging With Programmable Kvo Rate
OCCLUSION
Low, Medium, High Levels
PUMP STACKING
Multiple Pump Stacking with Normal or Optional Single Power Cord. Facility of Stacking of 2-3 Pumps with built in Stacking Clips, ensures more useful group application & in & portability around the hospital premises
Body Weight Mode (Optional)
Delivery rate is calculated Automatically based on Volume & time preselection or on values entered for patient body weight with drug parameters.
ALARMS Invalid
Occlusion, End of syringe, Low Battery, Syringe displaced, No Syringe, Wrong Syringe, Pre Alarm for END, rate, target Volume, Target Time, Target volume Pre-alarm, Mains Failure Alarm.
ACCURACY
Volume: +/-1%, Time:+/-1%
TIME LIMIT
Time from 00:01 To 23:59 (hramin) or more specially demanded
VOLUME LIMITS
From 0.1ml to capacity of the syringe
POWER
220 VAC, +/-10%, 50/60 Hz 12VA
BATTERY TYPE
Ni Mh. 12V. 1300 mA/Hr
BATTERY BACK-UP
5-6 Hrs (Typ.)@5ml/Hr Or more if specially demanded
BATTERY RECHARGING
20 Hrs. For Full Charging
STANDARDS
Tested as per IEC 60601.1 60601-1-2 60601-2-24
DISPLAY
Premium look with exclusive Blue Color Display (Only In infutak 405 Ex )
RS485/RS232 PORT
For Computer Interface Central Monitoring Station (Only In infutak 405 Ex )
PCA (Optional)
Upgradable to PCA With Double loop safety for PCA Dose and time ( Only In infutak 405 Ex)
All available standard brands of syringes. Custom Programmable to any brand Syringe.
FLOW RATE RANGE
0.1-999.9m/Hr (Depending on syringe size)
INFUSED VOLUME RANGE
0.1-999.9ml
BOLUS RATE & VOLUME
300-999.9ml/hr (Depending on syringe size), Volume is Programmable by user
BOLUS INTERVAL
A minimum interval of time can be preset between two Bolus dose to avoid accidental over infusion, 1 min to 24 Hrs.
PURGE FACILITY
KVO
To Prevent Needle Clogging With Programmable Kvo Rate
OCCLUSION
Low, Medium, High Levels
PUMP STACKING
Multiple Pump Stacking with Normal or Optional Single Power Cord. Facility of Stacking of 2-3 Pumps with built in Stacking Clips, ensures more useful group application & in & portability around the hospital premises
Body Weight Mode (Optional)
Delivery rate is calculated Automatically based on Volume & time preselection or on values entered for patient body weight with drug parameters.
ALARMS Invalid
Occlusion, End of syringe, Low Battery, Syringe displaced, No Syringe, Wrong Syringe, Pre Alarm for END, rate, target Volume, Target Time, Target volume Pre-alarm, Mains Failure Alarm.
ACCURACY
Volume: +/-1%, Time:+/-1%
TIME LIMIT
Time from 00:01 To 23:59 (hramin) or more specially demanded
VOLUME LIMITS
From 0.1ml to capacity of the syringe
POWER
220 VAC, +/-10%, 50/60 Hz 12VA
BATTERY TYPE
Ni Mh. 12V. 1300 mA/Hr
BATTERY BACK-UP
5-6 Hrs (Typ.)@5ml/Hr Or more if specially demanded
BATTERY RECHARGING
20 Hrs. For Full Charging
STANDARDS
Tested as per IEC 60601.1 60601-1-2 60601-2-24
DISPLAY
Premium look with exclusive Blue Color Display (Only In infutak 405 Ex )
RS485/RS232 PORT
For Computer Interface Central Monitoring Station (Only In infutak 405 Ex )
PCA (Optional)
Upgradable to PCA With Double loop safety for PCA Dose and time ( Only In infutak 405 Ex)
Additional information required