Matches the proximal humerus anatomy for optimal fit and stability.
Allows for clear X-ray imaging post-implantation.
Allows for the use of both locking and non-locking screws for versatile fixation strategies.
Locking mechanism reduces the risk of implant-related complications.
Specifications
Filos- Proximal Humerus Safety Lock Plate 3.5 - Standard is used in case of dislocation of 2-, 3-, & 4-fragment fracture of the proximal humerus, including fracture involving osteopenic bone & if there are pseudarthroses in the proximal humerus or if there are osteotomies in the proximal humerus (use filos long if fracture extended).
The Filos - Proximal Humerus safety Plate 3.5 - Standard is designed to match the anatomy of the proximal humerus. The plate is separately used for the right and left humerus.
The Filos - Proximal Humerus safety Plate 3.5 - Standard, Head Region of the plate accommodates Safety Lock Screw 3.5 mm- Self Tapping and Shaft region accommodates both Cortex Screw 3.5 mm-Self Tapping and Safety Lock Screw 3.5 mm-Self Tapping.
The Filos - Proximal Humerus safety Plate 3.5 - Standard is indicated for fractures, fracture-dislocations, osteotomies, and non-unions of the proximal humerus, particularly in osteopenic bone.
Matches the proximal humerus anatomy for optimal fit and stability.
Allows for clear X-ray imaging post-implantation.
Allows for the use of both locking and non-locking screws for versatile fixation strategies.
Locking mechanism reduces the risk of implant-related complications.
Specifications
Filos- Proximal Humerus Safety Lock Plate 3.5 - Standard is used in case of dislocation of 2-, 3-, & 4-fragment fracture of the proximal humerus, including fracture involving osteopenic bone & if there are pseudarthroses in the proximal humerus or if there are osteotomies in the proximal humerus (use filos long if fracture extended).
The Filos - Proximal Humerus safety Plate 3.5 - Standard is designed to match the anatomy of the proximal humerus. The plate is separately used for the right and left humerus.
The Filos - Proximal Humerus safety Plate 3.5 - Standard, Head Region of the plate accommodates Safety Lock Screw 3.5 mm- Self Tapping and Shaft region accommodates both Cortex Screw 3.5 mm-Self Tapping and Safety Lock Screw 3.5 mm-Self Tapping.
The Filos - Proximal Humerus safety Plate 3.5 - Standard is indicated for fractures, fracture-dislocations, osteotomies, and non-unions of the proximal humerus, particularly in osteopenic bone.